head
Flow sensors

SM6050
SMR12GGX10KG/US
Magnetic-inductive flow sensor
Connector
Process connection: G½ flat seal

Analogue output 4...20 mA
Measuring range
0...25 l/min
connection to pipe by means of an adapter
Made in Germany
 
Application Conductive liquids
(conductivity:>= 20 µS/cm / viscosity: < 70 mm²/s at 40 °C)
Electrical design DC
Output 4...20 mA analogue
 
Operating voltage [V]19...30 DC ¹)
Reverse polarity protection yes
Overload protection yes
Current consumption [mA]90
Power-on delay time [s]5
Analogue output 4...20 mA (max. 500 Ω)
Flow monitoring
Measuring range [l/min]0...25
 
Response time [s]< 0.150
Accuracy ± (2% MW + 0.5% MEW)
Repeatability ± 0.2% MEW
Pressure loss (dP) / flow rate (Q)
 
Ambient temperature [°C]-10...60
Medium temperature [°C]-10...70
Storage temperature [°C]-25...80
Protection IP 67, III
Insulation resistance [MΩ]> 100 (500 V DC)
Pressure rating [bar]16
Shock resistance
DIN IEC 68-2-27: 20 g (11 ms)
Vibration resistance
DIN IEC 68-2-6: 5 g (10...2000 Hz)
EMC
EN 61000-4-2 ESD:  4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated:  10 V/m
EN 61000-4-4 Burst:  2 kV
EN 61000-4-5 Surge:  0.5 kV
EN 61000-4-6 HF conducted:  10 V
Housing materials stainless steel 316L / 1.4404; PBT-GF 20; EPDM/X (Santoprene)
Materials (wetted parts) stainless steel 316L / 1.4404; PEEK (polyether ether ketone); FKM
Connection M12 connector; gold-plated contacts
 
Weight [kg]0.49
Remarks
¹) to EN50178, SELV, PELV
MW = measured value
MEW = final value of the measuring range
 
Wiring
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen  —  We reserve the right to make technical alterations without prior notice.  —  GB  —  SM6050  —  15.06.2009